UV Sterilizer for Drinking Water with 254 Nm UVC Germicidal Lamp
video
UV Sterilizer for Drinking Water with 254 Nm UVC Germicidal Lamp

UV Sterilizer for Drinking Water with 254 Nm UVC Germicidal Lamp

Various specifications UV sterilizer for drinking water, disinfection with the 254 Nm UVC light, no chemicals, high efficiency.

  • Hızlı Delievery
  • Kalite Güvencesi
  • 7/24 Müşteri Hizmetleri
ürün tanıtımı

FEATURES

1. Long lifespan

2. Efficient and safe

3. Good reliability and stability

4. Ozone-free

5. Beautiful appearance

6. Large production capacity

7. EPA, ISO9001, CE certified

1

SPECIFICATIONS

1. Type: Multitude stainless steel pipe

2. Peak Wavelength: 254nm

3. Input Voltage: 220vAC

4. Power: 8W-1650W

5. Disinfection volume: 5.5-150m3/hour

6. Water pressure: 0.6MPa

7. Diameter: 101-325mm

8. Operating Temperature Range: -10 degree - 100 degree

9. Materials: Quartz glass uvc tube, 304/316 stainless steel pipe

10. Lifespan: 10000 hours

2


ADVANTAGE

This series of products is particularly suitable for relatively large areas of water flow, such as various types of water plants, food plants, pharmaceutical companies, aquariums, farms and so on. Single water treatment capacity ranges from 5 tons per hour to 150 tons. The cavity is made of 304/316 stainless steel, which conforms to the international standard. Its appearance is beautiful and the quality is guaranteed. The polishing process on the inner wall has improved the sterilization efficiency. Full range of products is 0.6MPa pressure. The diameter of the inlet and outlet can be changed according to the customer's needs.

1


APPLICATIONS

Aquarium disinfection

Water treatment

Water purifier


2


Test method for ultraviolet dosage of overflow UV sterilizer

UV disinfection techniques have their advantages such as broad spectrum, fast, energy saving, no bistrois, etc., has been widely used in municipal water supply, drinking water disinfection, sewage treatment, and many fields such as food industry, electronics industry, pharmaceuticals. It is reasonable or not, the use effect is good, directly related to the health and safety of the public.

my country has also developed a lot of standards related to UV applications for the characteristics of different industries. like

1. According to the CJ / T204-2000 "Life Drinking Water UV Savory Surface", the sterilizer product of the new lamp is required, and the measured ultraviolet irradiation is not less than 12,000 μW • S / CM2. The ultraviolet irradiation dose measured by the normal working sterilizer shall not be less than 9000 μW • S / CM2.

2, according to GBT19837-2005 "City to Drainage UV Disinfection Equipment": Town Life Drinking Water Treatment UV irradiation dose is not less than 40mJ / cm2; urban sewage (1 grade A standard) sterilization treatment UV radiation dose is not less than 20MJ / CM2; urban sewage (1 stage B and 2 standard) sterilization treatment of ultraviolet irradiation dose of not less than 15 mJ / cm2.

3, according to the requirements of GB50014-2006 "Outdoor Drainage Design Specification", the second-stage treatment of water-proof the water is 15 to 22 mJ / cm2; the ultraviolet irradiation dose of the reclaimed water is 24 to 30 mJ / cm2.

The core parameters in the standard - ultraviolet irradiation dose, is the integral function of UV radiation intensity (I) and the time(T) to stay in the sterilizer during the sterilizer flow through the sterilizer. Usually expressed in dose,

That is: dose =IT (unit: mj / cm2)

The I is the ultraviolet radiation intensity of the lamp, the water is specifically flowed through the path in the bactericidator, the ultraviolet transmittance of water, the water particles, the transmission of the sleeve and the degree of fouling the sleeve wall. Impact, it is difficult to calculate it. And engineering we need a simple way to verify our design and manufactured bactericia, whether relevant national and industry standards are met to achieve the expected bactericidal effect.

3

Let's take a brief introduction to this method.

Referring to the requirements of GB / T 1937-2005, the specific operation method of the biological verification method is: 1, first use the parallel ultraviolet beam to measure the water sample with the ultraviolet rays of different radiation intensities, test the microbiology under different UV doses. The activity is obtained, and the corresponding relationship curve between the microbial inactivation rate and the UV dose is obtained. 2. Continuous flow of the same test water through the ultraviolet sterilizer, change its flow, monitor the microbial residual concentration of the stock outlet under different flow rates, resulting in the corresponding curve of the sterilizer flow and the microbial inactivation rate. 3. Configuring the inactivation rate and ultraviolet dose measured by parallel ultraviolet beams, we can know the equivalent ultraviolet dose that the sterilizer can provide at a certain amount of flow.

If we measure a biological verification method, the equivalent ultra-dose value of a sterilizer is greater than the relevant national or industry standard, we can know that the bactericidator can meet the sterilization requirements in the current situation. However, since the ultraviolet lamp is attenuated during use, the surface fouling of the sleeve affects the transmission of ultraviolet light, and we should leave the initial ultraviolet dose of the sterilizer(UV sterilizer for drinking water with 254nm UVC germicidal lamp) to make the sterilizer on the lamp. The end of the tube life can still meet the requirements of sterilization performance. Its calculation formula is:

ED = ND CLH CJG

ED: Efficient dose of ultraviolet sterilizer

ND: Equivalent UV dose measured by a new lamp new casing state

CLH: aging coefficient of ultraviolet lamp

CJG: The scale factor of the sleeve